POWERFUL SOLUTIONS. GLOBAL FORCE.
L2733 Rev. C 11/10
Thermoplastic Hydraulic Hoses and Fittings
1500 and 2000 Series
TABLE 1 - HOSE SPECIFICATIONS
Hose Model 1500 Series Thermoplastic (blue) 2000 Series Thermoplastic (red)
Material Construction
• Inner Tube: Polyoxymethylene (POM).
• Four (4) spiralized layers of high tensile steel wire.
• Outer Jacket: Blue Polyamide (PA).
• Inner Tube: Polyoxymethylene (POM).
• Six (6) spiralized layers of high tensile steel wire.
• Outer Jacket: Red Polyamide (PA).
Inside Diameter
0.20 inch [5,0 mm] 0.20 inch [5,0 mm]
Outside Diameter
0.44 inch [11,2 mm] 0.53 inch [13,4 mm]
Working Pressure
21,755 psi [1500 bar] 29,010 psi [2000 bar]
Burst Pressure
65,250 psi [4500 bar] 95,000 psi [6550 bar]
Minimum Bend Radius
5.9 inch [150 mm] 7.87 inch [200 mm]
Chemical Resistance
Suitable for all hydraulic oils and most solvents. Suitable for all hydraulic oils and most solvents.
Working Temperature
-20°F to +140°F [-29°C to +60°C] -20°F to +140°F [-29°C to +60°C]
Repair Parts Sheets for this product are available from the Enerpac
web site at www.enerpac.com, or from your nearest Authorized
Enerpac Service Center or Enerpac Sales offi ce.
1.0 IMPORTANT RECEIVING INSTRUCTIONS
Visually inspect all components for shipping damage. If any
shipping damage is found, notify carrier at once. Shipping damage
is NOT covered by warranty. The carrier is responsible for all repair
or replacement cost resulting from damage in shipment.
2.0 DESCRIPTION
Enerpac 1500 and 2000 Series thermoplastic hoses are intended
for use with high pressure hydraulic devices. Refer to Table 1
(below) for hose specifi cations and features.
WARNING: Do not use Enerpac 1500 Series hoses in
systems exceeding 21,755 psi [1500 bar]. Do not use
Enerpac 2000 Series hoses in systems exceeding
29,010 psi [2000 bar].
3.0 SAFETY INFORMATION
To avoid personal injury during system operation, read and follow
all CAUTIONS, WARNINGS, and INSTRUCTIONS included
with or attached to each product. ENERPAC CANNOT BE
RESPONSIBLE FOR DAMAGE RESULTING FROM UNSAFE
USE OF PRODUCT, LACK OF MAINTENANCE, OR INCORRECT
PRODUCT OR SYSTEM APPLICATION. Contact Enerpac when
in doubt about applications and safety precautions.
WARNING: Be certain that ALL system components,
including couplers, fi ttings and pipes, are rated for the
maximum operating pressure of the system. The system
operating pressure must not exceed the pressure rating of the
lowest rated component in the system or system failure may occur,
resulting in serious personal injury or equipment damage.
Index:
English. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3
Français. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6
Deutsch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-9
Italiano. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-12
Español . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13-15
Hollands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16-18
Português . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19-21
Suomalainen . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22-24
Norsk. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25-27
Svensk. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28-30
中文 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31-32
日本 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33-34
Page view 0
1 2 3 4 5 6 ... 35 36

Summary of Contents

Page 1 - 1500 and 2000 Series

Instruction SheetPOWERFUL SOLUTIONS. GLOBAL FORCE.L2733 Rev. C 11/10 Thermoplastic Hydraulic Hoses and Fittings1500 and 2000 Series TABLE 1 - HOS

Page 2 - 4.3 Maintenance

10Foglio IstruzioneTubi fl essibili idraulici e raccordi in termoplastico delle Serie 1500 e 2000 L2733 Rev. C 11/10 POWERFUL SOLUTIONS. GLOBAL FORCE

Page 3 - Fittings and Couplers

11AVVISO: Indossare sempre le adatte protezioni quando si lavora con un equipaggiamento idraulico.AVVISO: Accertarsi che tutti i componenti del sist

Page 4 - Fiche d’instructions

124.3 MANUTENZIONEThis section refers to components commonly found in a hydraulic system.Generalità1. Mantenere i componenti puliti in ogni momento.

Page 5 - 4.2 Accessoires

13Mangueras y conexiones hidráulicas termoplásticas Series 1500 y 2000Hoja de InstruccionesL2733 Rev. C 11/10 POWERFUL SOLUTIONS. GLOBAL FORCE.TABLA

Page 6 - Accessoires et raccords

14ADVERTENCIA: Lleve siempre equipo protector personal adecuado al operar equipo hidráulico.ADVERTENCIA: Asegurarse de que todos los componentes del

Page 7 - Bedienungsanleitung

154.3 MANTENIMIENTOEsta sección trata de los componentes que comúnmente se encuentran en un sistema hidráulicoGeneral1. Mantener los componentes lim

Page 8 - 4.2 Verschraubungen

16Thermoplastische hydraulische slangen en fi ttingen Series 1500 en 2000InstructiebladL2733 Rev. C 11/10 POWERFUL SOLUTIONS. GLOBAL FORCE.TABEL 1 –

Page 9 - Hydraulikschläuche

17WAARSCHUWING: Draag de juiste persoonlijke beschermende kleding wanneer hydraulische apparatuur wordt bediend.WAARSCHUWING: Zorg ervoor dat alle s

Page 10 - Foglio Istruzione

184.3 ONDERHOUDDeze Sectie heeft betrekking op onderdelen gewoonlijk aangetroffen in een hydraulisch systeem.Algemeen1. Houd de onderdelen altijd sch

Page 11 - 4.2 Raccordi

19Mangueiras Hidráulicas Termoplásticas e Conexões Séries 1500 e 2000 Folha de InstruçõesL2733 Rev. C 11/10 POWERFUL SOLUTIONS. GLOBAL FORCE.TABELA

Page 12 - Raccordi e accoppiatori

2WARNING: Always wear proper personal protective gear when operating hydraulic equipment.WARNING: Make sure that all system components are protected f

Page 13 - Hoja de Instrucciones

20ADVERTÊNCIA: Use sempre equipamento adequado de proteção ao operar o equipamento hidráulico.ADVERTÊNCIA: Tenha certeza de que todos os componentes

Page 14 - 4.2 Conexiones

214.3 MANUTENÇÃOEsta seção é direcionada aos componentes comumente encontrados em um sistema hidráulico.Geral1. Mantenha sempre os componentes limpos

Page 15 - Conectores y acopladores

22Termoplastiset hydrauliletkut ja -liittimet 1500- ja 2000-sarjatKäyttöohjeetL2733 Rev. C 11/10 POWERFUL SOLUTIONS. GLOBAL FORCE.TAULUKKO 1 – LETK

Page 16 - Instructieblad

23VAROITUS: Käytä aina henkilökohtaisia suojavarusteita, kun käytät hydraulilaitteita.VAROITUS: Varmista, että järjestelmän kaikki osat on suojattu

Page 17 - 4.2 Fittingen

244.3 KUNNOSSAPITOTässä kappaleessa viitataan hydraulijärjestelmän yleisimpiin osiin.Yleistä1. Pidä osat aina puhtaina. Monet hydraulijärjestelmän on

Page 18 - Fittingen en koppelingen

25Termoplastiske hydraulikkslanger og koblinger Serie 1500 og 2000InstruksjonsmanualL2733 Rev. C 11/10 POWERFUL SOLUTIONS. GLOBAL FORCE.TABELL 1 -

Page 19 - Folha de Instruções

26ADVARSEL: Bruk alltid passende personlig verneutstyr når du bruker hydraulisk utstyr.ADVARSEL: Påse at alle systemkomponenter beskyttes mot ekstern

Page 20 - 4.2 Conexões

27Hydraulikkslanger1. Hydraulikkslanger bør oppbevares i esken til de skal brukes.2. Slanger bør oppbevares ved temperaturer mellom 10º til 24 ºC [

Page 21 - Conexões e Engates Rápidos

28Termoplastiska hydraulslangar och anslutningar 1500- och 2000-serienInstruktionsbladL2733 Rev. C 11/10 POWERFUL SOLUTIONS. GLOBAL FORCE. TABELL 1

Page 22 - Käyttöohjeet

29VARNING: Bär alltid korrekt personlig skyddsutrustning vid arbete med hydraulisk utrustning.VARNING: Se till att alla systemkomponenter är skyddad

Page 23 - 4.2 Liittimet

3Hydraulic Hoses1. Hydraulic hoses should be left in carton until needed.2. Store hoses at a temperature between 50º to 75ºF [10º to 24ºC] and at a

Page 24 - Liittimet

30Hydraulslangar1. Hydraulslangarna bör lämnas i kartongen tills de ska användas.2. Förvara slangarna vid en temperatur mellan 10º till 24 ºC (50 t

Page 25 - Instruksjonsmanual

31说明书热塑液压软管及管件1500 和 2000 系列L2733 Rev. C 11/10 POWERFUL SOLUTIONS. GLOBAL FORCE.表 1 – 软管规格 软管型号1500 系列热塑(蓝色) 2000 系列热塑(红色)材料结构• 内管:聚甲醛 (POM)• 四层螺旋化高

Page 26 - Generelt

32 警告 请勿触摸加压的软管。发生漏油时请远离该区域,并立即更换所有泄漏或损坏的软管。警告 从小孔中漏出的高压液压油可穿透甚至割破皮肤,导致严重的人身伤害甚至血液中毒。如果液压油射入皮肤,或将皮肤划伤,请立即就医。警告 切勿对未连接(断开连接)的公接头背面施加压力。在

Page 27 - Plugger og koblinger

33熱可塑性油圧ホースおよび継手1500および2000シリーズ説明シートL2733 Rev. C 11/10 POWERFUL SOLUTIONS. GLOBAL FORCE.表1 ‒ ホースの仕様 ホースのモデル1500 Series Thermoplastic (blue) 2000 Ser

Page 28 - Instruktionsblad

34警告 加圧中は、ホースを取り扱わないでください。オイル漏れから離れてください。漏れているまたは損傷しているホースは直ちに交換してください。警告 高圧状態の油圧オイルが小さな穴から噴き出して、皮膚を貫通または傷付ける危険性があります。重大な人身障害や血液中毒の原因となります。オイルが皮膚の

Page 30 - Anslutningar och kopplingar

AfricaENERPAC Middle East FZEOffi ce 423, JAFZA 15P.O. Box 18004Jebel Ali, DubaiUnited Arab EmiratesTel: +971 (0)4 8872686Fax: +971 (0)4 8872687Aust

Page 31 - 1500 和 2000 系列

4Fiche d’instructionsFlexibles et raccords hydrauliques thermoplastiques Séries 500 et 2000L2733 Rev. C 11/10 POWERFUL SOLUTIONS. GLOBAL FORCE.TABLE

Page 32

5AVERTISSEMENT: Toujours porter un équipement de protection individuelle lors de l'utilisation de l'équipement hydraulique.AVERTISSEMENT:

Page 33 - 1500および2000シリーズ

64.3 GénéralitésThis section refers to components commonly found in a hydraulic system.General1. S’assurer que les composants soient toujours propre

Page 34 - 4.3 メンテナンス

7 BedienungsanleitungThermoplastische Hydraulikschläuche und -verschraubungen Serie 1500 und 2000L2733 Rev. C 11/10 POWERFUL SOLUTIONS. GLOBAL FORCE

Page 35

8WARNUNG: Tragen Sie immer ordnungsgemäß persönliche Schutzausrüstung, wenn Sie Hydraulikgeräte betreiben.WARNUNG: Stellen Sie sicher, dass alle Sys

Page 36 - Enerpac Worldwide Locations

94.3 WARTUNGDieser Abschnitt bezieht sich auf Komponenten, die normalerweise in einem Hydrauliksystem vorhanden sind.Allgemeine1. Halten Sie die Komp