L14004710 rev: preliminary F 03/07/14
1.0 SAFETY & GENERAL INFORMATION
Read all instructions, warnings and
cautions carefully. Follow all safety
precautions to avoid personal injury or
property damage during system operation.
Enerpac cannot be responsible for damage or injury
resulting from unsafe product use, lack of maintenance
or incorrect product and/or system operation. Contact
Enerpac when in doubt as to the safety precautions
and operations. If you have never been trained on
high-pressure hydraulic safety, consult your distribution
or service center for a free Enerpac Hydraulic safety
course.
Failure to comply with the following cautions and
warnings could cause equipment damage and personal
injury.
A CAUTION is used to indicate correct operating or
maintenance procedures and practices to prevent
damage to, or destruction of equipment or other
property.
A WARNING indicates a potential danger that requires
correct procedures or practices to avoid personal
injury.
A DANGER is only used when your action or lack of
action may cause serious injury or even death.
2.0 SAFETY PRECAUTIONS
WARNING: Stay clear of loads supported by
hydraulics. A cylinder, when used as a load
lifting device, should never be used as a load
holding device. After the load has been
raised or lowered, it must always be blocked
mechanically.
WARNING: use only rigid pieces to hold
loads. Carefully select steel or wood blocks
that are capable of supporting the load.
Never use a hydraulic cylinder as a shim or spacer in
any lifting or pressing application.
WARNING: Wear proper personal protective
gear when operating hydraulic equipment.
DANGER: To avoid personal injury keep
hands and feet away from cylinder and
workpiece during operation.
WARNING: Do not exceed equipment
ratings. Never attempt to lift a load weighing
more than the capacity of the cylinder.
Overloading causes equipment failure and possible
personal injury.
CAUTION: Do not connect a jack or cylinder
to a pump with a higher pressure rating.
Never set the relief valve to a higher
pressure than the maximum rated pressure
of the pump. Higher settings may result in
equipment damage and/or personal injury.
WARNING: The system operating pressure
must not exceed the pressure rating of the
lowest rated component in the system.
Install pressure gauges in the system to monitor
operating pressure. It is your window to what is
happening in the system.
OPERATING MANUAL
SFP SERIES
Index:
1.0 SAFETY & GENERAL INFORMATION ............ 1
2.0 SAFETY PRECAUTIONS ................................. 1
3.0 SPECIFICATIONS ............................................ 2
4.0 INSTALLATION ................................................ 3
5.0 OPERATION ..................................................... 4
6.0 MAINTENANCE ................................................ 5
7.0 TROUBLESHOOTING GUIDE ......................... 5
8.0 ATTACHED DOCUMENTATION TABLE ......... 6
1
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - OPERATING MANUAL

L14004710 rev: preliminary F 03/07/14 1.0 SAFETY & GENERAL INFORMATION Read all instructions, warnings and cautions carefully. Follow all safet

Page 2 - 3.0 SPECIFICATIONS

CAUTION: Avoid damaging hydraulic hose. Avoid sharp bends and kinks when routing hydraulic hoses. Using a bent or kinked hose will cause severe backp

Page 3 - 4.3 Hydraulic connections

4.0 INSTALLATION Visually inspect all components for shipping damage. Shipping damage is not covered by warranty. If shipping damage is found, notify

Page 4

4.4 Flow level Check the oil level of the pump prior to start-up, if necessary add oil by removing the plug from the top of the reservoir. The reser

Page 5

Now the machine is able to work. Use the manual valves to move the cylinders as explained in the paragraph 5.1. 5.4.2 Pumps with solenoid valves To t

Page 6 -    

7.1 Troubleshooting chart 8.0 ATTACHED DOCUMENTATION TABLE In this manual other documents have been attached which are necessary to interpret this man